![]() ![]() “Maintenance” is a thorough examination and repair, as needed, of your facility’s portable fire extinguishers and is covered in NFPA 10(98), Sec. Portable Fire Extinguisher Annual Tests, Inspections and Maintenance ![]() Non rechargeable extinguishers can be identified by looking for markings similar to the following: “Discharge and Dispose of After Any Use”, “Discharge and Return to Manufacturer After Any Use”, or simply “Non-rechargeable”.When any of the conditions noted in Item 1 on the previous page, with the exception of a broken or missing safety seal, are found during an inspection of a non-rechargeable dry chemical extinguisher, the extinguisher must be removed from use. ![]() Pressure gauge readings are not in the operable range or position.There is evidence of physical damage, corrosion, leakage or a clogged nozzle.Fullness can’t be confirmed (as determined by weighing or lifting).Full maintenance procedures must be performed whenever an inspection of a rechargeable fire extinguisher reveals any of the following problems :.Some problems trigger a need for full maintenance or even replacement of the extinguisher. Obviously, any problems found during the monthly inspection must be corrected immediately. Where circumstances warrant, some fire extinguishers may have to be inspected more frequently.Įxamples of such circumstances might include extinguishers that are oftentimes found obstructed during monthly inspections or extinguishers located in areas where they are subject to tampering, theft or mechanical injury.Fullness – confirmed by weighing or lifting.Operating instructions are legible and facing outward.Pressure gauge readings are in the proper range or position.There is no evidence of physical damage, corrosion, leakage or clogged nozzle.There are no obstructions to access or visibility.Extinguishers are in their designated places.4-3.2, therefore, requires that the monthly inspection verify a number of things including: A broken seal, for example, may be an indication that someone has used the extinguisher and discharged a portion of the contents too small to affect the pressure gauge. These visual inspections, intended to help ensure that each extinguisher is in its designated place and will operate if needed, can be performed by facility staff.Ī pressure gauge in the “normal” or “operable” range is not a 100 percent guaranty that the extinguisher will perform as intended. Portable fire extinguishers are required to be visually inspected when initially placed in service and at least monthly thereafter. Portable Fire Extinguisher Visual Inspections Visit NFPA to purchase the newest version of the NFPA 10 standards and codes. 2.1.1 references the 1998 edition of NFPA 10. 9.7.4.1 require that portable fire extinguishers be inspected and maintained in accordance with NFPA 10, Standard for Portable Fire Extinguishers. NFPA 10: Fire Extinguisher Tests, Inspections & Maintenance ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |